Periodic inspection and inspection of structures, integrated into the field pass.
Routine visual inspection, special inspection of bridges and structures and retroreflectivity measurement — to standard, with a georeferenced photographic record and no mobilisation beyond the continuous survey.
When to engage
Mandatory periodic inspection
The regulatory agencies require routine and special inspections.
Structural risk in bridges
Bridges and structures require a special inspection under DNIT 010/2004 — the basis for prioritising recovery works.
Signage at night in doubt
Retroreflectivity is a recurring item in contractual supervision. We measure reflectivity safely, without disrupting traffic.
Sub-services — Inspection
Routine visual inspection
Detailed inspection of the condition of the road and its elements, with a georeferenced photographic record.
Special inspection of structures (DNIT 010/2004)
Inspection of bridges and viaducts under the DNIT 010/2004 standard.
Retroreflectivity inspection
Retroreflectivity of horizontal and vertical signage, measured continuously with a retroreflectometer in accordance with NBR 14723.
How we deliver
Scheduling to standard
Inspection plan by type — routine, continuous, special inspection of structures — and by contractual requirement.
Field inspection
Continuous inspection integrated into the CVS pass; special inspection of structures and retroreflectivity with a dedicated team and equipment.
Georeferenced record
Defects and measurements photographed, georeferenced and linked to the corresponding element.
Technical record
Inspection report by section and by inspected element, to standard.
What you receive
- Inspection report by section and by inspected element, to standard
- Georeferenced photographic record of the elements visited and their defects
- Retroreflectivity measurements by section and signage type
- Geographic databases compatible with most GIS systems
Technical specifications
| Inspection types | Routine and continuous · bridges and structures · retroreflectivity |
|---|---|
| Reference standards | DNIT 010/2004 (structures) · NBR 14723 (retroreflectivity) |
| Equipment | Calibrated retroreflectometer, measurement by section and signage type |
| Record | Photographic and georeferenced, linked to the section and to the video frame |
| Delivery | Inspection report by section and by inspected element · geographic database |
Frequently asked questions
No. The continuous inspection is integrated into the CVS pass — with no extra mobilisation. The special inspection of structures is scheduled according to the standard.
The special inspection of bridges and structures follows DNIT 010/2004, with a georeferenced photographic record of defects.
The retroreflectivity of horizontal and vertical signage is measured with a calibrated retroreflectometer, by section and signage type, in accordance with NBR 14723.
The report is technical and independent, with a georeferenced record — used in designs, licences, expert assessments and financing processes.
The condition classification by section and element orders the interventions — the technical basis for the maintenance and recovery programme.
Do you have a periodic inspection or an inspection of structures to carry out?
Inspection to standard, integrated into the field capture. Talk to a specialist.